Aircare MA0800 Bedienungshandbuch Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
6
CONTROL PANEL
Digital Display
1) Press the power button once to turn
the unit on*. Initially there is a slight
delay while the electronics calibrate.
2) Two bars (- -) appear during this
time. Once calibration is complete a
ROOM humidity reading between
20% - 95% will be displayed. A
flashing 20 display indicates that the
room humidity is less than 20%.
NOTE: The default settings at initial startup are (LOW) F1 fan speed and 65%
SET humidity. After desired settings are selected by the user, they remain as long
as the unit remains plugged in and there is no power interruption. When the unit is
unplugged, the original default settings are reinstated.
* Humidifier fan should operate at initial start up. If it does not, refer to Trouble Shooting Table.
HUMIDITY SETTING.
3) Press this button to adjust the humidity to suit your needs.
This humidifier will automatically cycle on and off as
required to maintain the selected setting. The readout
displays both actual and desired (SET) humidity percentage
(%) settings when humidity control button is pressed.
4) The readout has a range of 20% to 95% Relative Humidity
(RH). If the room humidity level is equal to or less than 20%
RH the display will show a flashing 20. The SET readout
has a range of 25% to 65% RH and is adjusted in
increments of 5%. Initially depressing the humidity button
will display the current humidity setting. Each additional
press of the button increases the setting by 5%.
A SET point of 65% RH operates the humidifier continuously until the tank is
empty, regardless of the ROOM reading.
The humidistat that senses the readings is located on the power cord.
Ensure that it is free from obstruction.
FAN SPEED
5)
This humidifier is equipped with a 3-speed fan control.
Initially depressing the speed button will display the current
speed setting. Each push of the speed button advances the
mode through the settings of (HIGH) F3, (MEDIUM) F2,
(LOW) F1 and (AUTO) A.
6)
When (AUTO) A is selected the humidifier will determine
the required fan speed needed to bring the actual room
humidity up to the set humidity.
NOTE: When excessive condensation exists, a lower speed
setting is recommended.
Seitenansicht 5